- Smoke alarms are compulsory in Australian homes and must meet AS 3786
- Smoke alarm rules vary by state and territory
- Smoke alarms should be tested monthly and replaced every 10 years
Key takeaways
At Allianz, we’ve been insuring Australian homes for over 100 years. We understand how important it is that your smoke alarms meet local regulations. By law, all smoke alarms must meet Australian Standard 3786, but how and where you install them can differ. Here’s everything you should know about rules in your area.
Common smoke alarm terms
- Interconnected: when one alarm activates, they all sound
- Photoelectric: uses a light sensor to detect smoke
- Ionisation: uses small electrical current to detect smoke
- Hardwired: connected to the home’s mains electricity
Queensland
By 1 January 2027, all homes in Queensland (QLD), including registered caravans and motorhomes, must have working interconnected photoelectric smoke alarms that:
- are under 10 years old
- don’t have an ionisation sensor
- are hardwired or powered by a non-removable 10-year battery
Private homes, townhouses, and units must have an alarm on every storey. Place them in all bedrooms and hallways or areas connecting bedrooms with the rest of the home. A licensed electrician must install all hardwired alarms.
For more information, see Queensland Fire Department.
New South Wales
While New South Wales (NSW) law doesn’t specify between photoelectric or ionisation, Fire and Rescue NSW recommend that you install hardwired interconnected smoke alarms.
Position your smoke alarms in hallways near bedrooms or between sleeping areas and the rest of the home. An alarm should be on every storey. Fire and Rescue NSW advise installing smoke alarms in each bedroom for greater protection. For caravans and motorhomes, place a smoke alarm where the bed is. One must also be placed in the annex if people are sleeping there.
For more information or to book a home safety visit, see Fire and Rescue NSW.
Victoria
Smoke alarm laws in Victoria (VIC) depend on when your home or building was built or largely renovated. They don’t distinguish between photoelectric or ionisation, but mandate what powers your alarm.
- Before 1 August 1997: homes may have battery-powered alarms
- After 1 August 1997: homes require hardwired alarms with battery backup
- After 1 May 2014: homes must have interconnected hardwired alarms with battery backup
Your house, unit, townhouse, or caravan must have an alarm placed between each sleeping area and the rest of your home. An alarm should be on every storey. Fire Rescue Victoria recommend you place working smoke alarms in every bedroom and living area.
For more information, see Fire Rescue Victoria and Country Fire Authority.
South Australia
Smoke alarms in South Australia (SA) can be photoelectric or ionisation, but the power source depends on when your home’s construction was approved.
- Before 1 January 1995: alarms can be powered by a replaceable battery unless ownership changed on or after 1 February 1998. If ownership changed, alarms must be hardwired or have 10-year non-replaceable, non-removable, permanently connected batteries.
- From 1 January 1995: alarms must be hardwired with a backup battery
- From 1 May 2014: homes with multiple residents must have interconnected hardwired alarms
Smoke alarms in SA must be installed in locations that will provide reasonable warning to people sleeping in the home.
For recreational vehicles (RVs), it’s recommended that you use a photoelectric smoke alarm with a 10-year non-replaceable, non-removable battery.
Western Australia
Western Australian (WA) law doesn’t mandate between detection types. However, the Department of Fire and Emergency Services (DFES) recommend photoelectric smoke alarms.
Smoke alarms in WA must be hardwired and no more than 10 years old. For homes approved for build after 1 May 2015, all smoke alarms must be interconnected. Battery-powered alarms are only allowed where there aren’t any appropriate places to wire the alarm.
Your smoke alarms must be installed in every hallway or corridor linked to a bedroom or between the bedrooms and the rest of the home. An alarm should be on every storey.
WA DFES recommends interconnected smoke alarms in all bedrooms, living rooms, hallways, stairways, and garages.
There aren’t any separate smoke alarm requirements for caravans, motorhomes or other RVs. Consider following similar placement rules to that of your house.
For more information, see Government of Western Australia and WA DFES.
Tasmania
Tasmanian (TAS) smoke alarm requirements depend on when your home was built or substantially renovated. The law doesn’t require all homes to have photoelectric alarms, although it’s recommended by Tasmania Fire Service.
For homes constructed or substantially renovated:
- Before 1 August 1997: requirements depend on the Building Code in force at the time
- From 1 August 1997: Smoke alarms must be hardwired to mains power
- From 1 May 2014: smoke alarms must be interconnected and hardwired.
For rental properties, smoke alarms must be hardwired or use a non-replaceable battery, regardless of when the home was constructed.
Smoke alarms must be installed in every hallway connected to bedrooms or between the bedrooms and the rest of the home. An alarm should be on every storey. Tasmania Fire Service advises smoke alarms in every bedroom, all hallways, living areas, at the top of the stairs, and in the garage.
While there aren’t any separate requirements for caravans or motorhomes, it’s recommended to place your smoke alarms in any sleeping area.
For more information, see the Tasmania Fire Service.
Australian Capital Territory
Australian Capital Territory (ACT) law doesn’t specify a detection type. However, ACT Emergency Services Agency encourages you to replace expired or faulty ionisation smoke alarms with photoelectric.
Homes built:
- Before 1 November 1994: can use battery-operated alarms
- From 1 November 1994: must use hardwired alarms
Smoke alarms should be installed on every storey and in bedrooms or in corridors leading to bedrooms. Multi-level homes must have a smoke alarm on every level, and the alarms must be interconnected.
For better safety, you’re advised to install smoke alarms in every bedroom.
For caravans and motorhomes, consider following similar placement rules to that of your house.
For more information, see ACT Emergency Services Agency.
Northern Territory
Northern Territory (NT) law requires all homes and caravans to have photoelectric smoke alarms. These must be hardwired or fitted with a sealed lithium battery with a 10-year life. All new or renovated homes from 1 May 2014 should have interconnected smoke alarms.
Existing ionisation alarms may remain in some owner-occupied homes until they stop working. However, you must replace them with an approved photoelectric alarm if:
- the alarm stops working
- the property is sold
- the property is rented or the tenancy is renewed or extended
- a hire agreement is entered into, renewed, or extended
Smoke alarms should be installed between each bedroom and the rest of the home. An alarm should be on every storey. If anyone sleeps with their door shut, an alarm should also be placed in their bedroom.
For more information, see Northern Territory Government and NT Fire and Rescue Service.
Where to install smoke alarms
Where you install smoke alarms depends on where you live and your type of home. As a general guide, install smoke alarms:
- in hallways or areas connecting bedrooms with the rest of the home
- on every level of a multi-storey home
- in other parts of the home where required by local building rules
Fire services often recommend installing an alarm in every bedroom, not just in the hallway outside. This is especially important if anyone sleeps with their bedroom door closed.
Avoid positioning ordinary smoke alarms too close to cooking appliances, bathrooms, ceiling fans, or air-conditioning vents.
Should I put a smoke alarm in my garage?
While smoke alarms aren’t required to be installed in garages, our data shows that 32% of house fires in 2025 affected sheds or garages.
Chris Wood, Emerging Risks Manager at Allianz Australia, recommends that Aussies “make it a priority to install an interconnected heat alarm rather than a smoke alarm, which can be triggered by dust and exhaust. Interconnected alarms allow the garage to ‘talk’ to the rest of the house.”
Smoke alarm rules for rentals
If you rent out your home, you may have extra responsibilities when it comes to smoke alarms. These rules vary by state and territory.
Swipe to view more
|
State or Territory |
What landlords need to know |
|
|
Test and clean alarms within 30 days before a new or renewed tenancy. Rental properties must already meet QLD’s interconnected photoelectric alarm rules. |
|
|
| NSW |
Check alarms every year. Repair or replace a faulty alarm within two business days of finding out about the problem. |
|
| VIC |
Arrange a smoke alarm check at least once every 12 months. Give renters written information about using and testing the alarms. |
|
| SA |
Install and maintain working alarms. Landlord is responsible even if the tenant is given routine tasks. |
|
| WA |
Make sure alarms comply before offering the home for rent. They must be working, generally hardwired, and no more than 10 years old. |
|
| TAS |
Use hardwired alarms with backup power or alarms with a built-in 10-year battery. Check them before a new tenant moves in. |
|
|
Make sure the required alarms are installed and working. Arrange repairs when needed. |
|
|
|
Test and clean alarms within 30 days before a tenancy starts. A new or renewed tenancy may also require an upgrade to a photoelectric alarm. |
|
Landlords and tenants: what's different?
Landlords and tenants have different responsibilities when it comes to smoke alarms.
Swipe to view more
|
Landlord |
Tenant |
|
Install smoke alarms of the required type in the correct locations
|
Notify landlord or property manager as soon as an alarm is missing, damaged, beeping, or not working
|
|
Make sure alarms are working at the start of a tenancy
|
Allow reasonable access for inspection, testing, repair, or replacement
|
|
Arrange required inspections, testing and maintenance
|
Test or clean alarms if required
|
|
Replace expired, faulty, or damaged alarms
|
Follow smoke alarm instructions provided by the landlord
|
|
Organise repairs promptly after being notified of a fault
|
Don’t remove, cover, paint over, disable, or interfere with an alarm
|
|
Use a licensed electrician where work on a hardwired alarm is required
|
Tell landlord if you change a removable battery or arrange an urgent repair
|
|
Keep any inspection, maintenance, or compliance records required in their state or territory
|
How to test and maintain your smoke alarms
Taking care of your smoke alarms is a simple task that can make a big difference. Old alarms can become less reliable, so it’s important to stay on top of testing and maintenance.
Swipe to view more
|
What |
How |
When |
| Test | Press and hold the test button until the alarm sounds |
Every month |
| Clean |
Vacuum dust and insects from around alarm vents |
Every six months |
| Change |
Change battery following manufacturer’s instructions |
Every 12 months |
| Replace |
Get a licensed electrician to replace your hardwired alarm or follow manufacturer’s instructions for all other types |
Every 10 years |
Depending on where you live, you may be eligible for our Home Health Check. An Allianz Home Safety Specialist will check that your smoke alarms work as part of the service.
Your smoke alarm compliance checklist
Take the next step with our Home Self-Check
Working smoke alarms can give you and your family more time to escape a fire. To help keep everyone safe, install them according to the laws in your state or territory, and check them regularly.
Keeping your home safe and well maintained can also help you meet your general obligations under your home insurance policy.
Smoke alarms are only one part of caring for your home. Use the Allianz Home Self-Check for simple checks that can help you keep your home safe and spot problems early.
Helping you prepare today to look after tomorrow. For expert home and car care resources, check out the hub.
Disclaimer
This article has been prepared by Allianz Australia Insurance Limited ABN 15 000 122 850 AFSL234708 ("Allianz"). It is a summary of key concepts and not meant to represent the complete picture on any given matter. It is not meant to be legal advice. The information should be read in conjunction with the relevant legislation and regulations. In some cases, information has been provided to us by third parties and while that information is believed to be accurate and reliable, its accuracy is not guaranteed in any way.
Any opinions expressed constitute our views at the time of issue and are subject to change. Neither Allianz, nor its employees or directors give any warranty of accuracy or accept responsibility for any loss or liability incurred by you in respect of any error, omission or misrepresentation in this article.
Any advice here does not take into account your individual objectives, financial situation or needs. Terms, conditions, limits, and exclusions apply. Before making a decision about this insurance, consider the relevant Product Disclosure Statement (PDS)/Policy Wording and Supplementary PDS (if applicable). Where applicable, the PDS/Policy Wording, Supplementary PDS and Target Market Determination (TMD) for this insurance are available on this website. We do not provide any form of advice if you call us to enquire about or purchase a product.
Allianz Australia Insurance Limited ABN 15 000 122 850 AFS Licence No. 234708 is the insurer of any general insurance products offered, and Allianz Australia Life Insurance Limited ABN 27 076 033 782 AFS Licence No. 296559 is the insurer of any life insurance products offered. Each entity is responsible for any statements and representations made about its products, on this website.